Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12622001045707
Ethics application status
Approved
Date submitted
12/03/2022
Date registered
28/07/2022
Date last updated
30/08/2024
Date data sharing statement initially provided
28/07/2022
Type of registration
Prospectively registered
Titles & IDs
Public title
Towards custom fitting continuous positive airway pressure (CPAP) devices for premature infants
Query!
Scientific title
Using a 3D scanner to investigate nasal injuries from CPAP devices in premature infants.
Query!
Secondary ID [1]
306667
0
Nil known
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
COMFIT
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Prematurity
325604
0
Query!
Bronchopulmonary dysplasia
325605
0
Query!
CPAP complications
325606
0
Query!
Condition category
Condition code
Reproductive Health and Childbirth
322966
322966
0
0
Query!
Complications of newborn
Query!
Respiratory
323711
323711
0
0
Query!
Other respiratory disorders / diseases
Query!
Public Health
323712
323712
0
0
Query!
Health service research
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
A member of the clinical team will perform (up to 30 seconds) 3D facial scans on each participant, in the infant's cot, in the intensive care nursery. 3D facial scans will not affect participant treatment in any way. Scans will only occur during the baby's cares when the CPAP device is removed for short periods of time for cleaning and to inspect for injuries as part of routine care. CPAP will be reapplied between each scan. The first scan will occur as soon as possible after starting CPAP therapy and again at 14 days after starting CPAP. The scanner used to capture the data will be the most optimal 3D scanners, identified prior to this study. These scanners will be one of the 3D scanners selected from a pool of scanners [Artec Leo, ipad 12, Bellus, Revopoint or a photogrammetry custom made rig](to be decided in the preceding phase of the study, which involves identifying the optimal scanners using a manikin or 3D printed model (simulacrum)). Scanning personnel will be trained to perform clinical scans. All scans performed will be reviewed promptly by members of the research team, to ensure the image acquired is adequate for data collection.
Query!
Intervention code [1]
323109
0
Early detection / Screening
Query!
Comparator / control treatment
All premature infants will be scanned with the 3D scanner and assessed for face size, shape and presence of injuries. The facial features of those who are free from injury, acquire single facial injury, and acquire multiple facial injuries (and severity of injuries) will be compared.
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
330732
0
Feasibility of 3D scanning of facial features of preterm infants on CPAP, including nostril size, nostril shape, nostril symmetry, septal (columella) width, bridge width or height, or distances between any of these landmarks, surface feature deviation analysis (voxel by voxel) by 3D scans. Feasibility of 3D scanning will be assessed through the scan quality and ability to visualise anatomical landmarks, measured on a rating scale by four independent assessors.
Query!
Assessment method [1]
330732
0
Query!
Timepoint [1]
330732
0
Timepoint 1: As soon as possible after starting CPAP therapy, up to the 3rd instance of CPAP initiation.
Timepoint 2: 14 days after the first scan or ceasing CPAP, whichever comes first.
Query!
Secondary outcome [1]
409963
0
Stage of nasal injury from CPAP device, measured by the stage of skin injury, will be assessed by the bedside nurse. Stage 0 - no injury, stage 1 - non-blanchable erythema, stage 2 - partial thickness skin loss (shallow ulcer), stage 3 - full thickness skin loss, stage 4 - full thickness tissue loss, stage 5 - unstageable, depth unknown.
Query!
Assessment method [1]
409963
0
Query!
Timepoint [1]
409963
0
At the time of the 3D facial scans - as soon as possible after starting CPAP therapy and at 14 days after starting CPAP or at CPAP completion, whichever occurs first.
Query!
Secondary outcome [2]
409964
0
Determine clinician acceptability of scanning. This will be determined by a short 3 question survey at the time of scanning, specifically designed for this study. Q1. 3D scanning did not adversely interfere with clinical care delivery (5 point likert scale - strongly disagree etc.), Q2. What changes were required to the neonatal care delivery area to complete scan? (Check box: room lighting, cot, mattress tilt, equipment, other...). Q3. I think 3D scanning and printing will improve the neonatal CPAP experience (5 point likert scale).
Query!
Assessment method [2]
409964
0
Query!
Timepoint [2]
409964
0
This will occur at the time of scanning by clinicians who are using or observing the 3D facial scans.
Query!
Secondary outcome [3]
409965
0
Duration of scans. This will be assessed at the time of each scan using the data collection form designed specifically for the study. The date and time at the start of scanning and at the end of scanning will be recorded.
Query!
Assessment method [3]
409965
0
Query!
Timepoint [3]
409965
0
This will occur at the time of 3D facial scanning.
Query!
Secondary outcome [4]
439262
0
3D scan facial features of preterm infants, including columella width
Query!
Assessment method [4]
439262
0
Query!
Timepoint [4]
439262
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [5]
439263
0
3D scan facial features, including philtrum
Query!
Assessment method [5]
439263
0
Query!
Timepoint [5]
439263
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [6]
439264
0
3D scan facial features, including philtrum
Query!
Assessment method [6]
439264
0
Query!
Timepoint [6]
439264
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [7]
439265
0
3D scan facial features including upper lip
Query!
Assessment method [7]
439265
0
Query!
Timepoint [7]
439265
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [8]
439266
0
3D scan facial features including upper lip
Query!
Assessment method [8]
439266
0
Query!
Timepoint [8]
439266
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [9]
439267
0
3D scan facial features of preterm infants including lower lip
Query!
Assessment method [9]
439267
0
Query!
Timepoint [9]
439267
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [10]
439268
0
3D scan facial features of preterm infants including lower lip
Query!
Assessment method [10]
439268
0
Query!
Timepoint [10]
439268
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [11]
439269
0
3D scan facial features of preterm infants, including bridge width or height
Query!
Assessment method [11]
439269
0
Query!
Timepoint [11]
439269
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Secondary outcome [12]
439270
0
3D scan facial features of preterm infants, including bridge width or height
Query!
Assessment method [12]
439270
0
Query!
Timepoint [12]
439270
0
Cumulative data will be assessed at the conclusion of the data collection period.
Query!
Eligibility
Key inclusion criteria
Infants born <30 weeks gestation and/or <1250g who require CPAP therapy for at least 5 days or more.
Query!
Minimum age
6
Hours
Query!
Query!
Maximum age
5
Months
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
Infants born with a facial congenital abnormality or infants with a poor prognosis and who may require redirection of care (palliation). Infants who are on non-invasive intermittent positive pressure ventilation (NIPPV) or requiring >8cm CPAP or >40% oxygen, or who are deemed too unwell for handling at the time scan is due. Change made after
Query!
Study design
Purpose of the study
Diagnosis
Query!
Allocation to intervention
Non-randomised trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Query!
Masking / blinding
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Query!
Statistical methods / analysis
A cohort of preterm infants who meet inclusion criteria and whose parents consent to participate, will be recruited as study participants. Recruitment will continue until at least 20 preterm infants with CPAP injuries and 20 preterm infants without CPAP injury have been recruited (maximum 40 infants). In order to give some indication of sample size, we calculate a sample size based on a conservative estimate of variation, in a well-studied anatomical measurement in preterm infants (head circumference at 28 weeks gestational age). In this case, we aim to find a significant difference in two relative distances between landmarks of 20% between groups in a population with a natural standard deviation in measurements of 20% (Cohen’s D = 1). This results in a sample size of n~40 (20 per group), at 80% power, when using exploratory Student’s t-tests and a correction for multiple comparisons based on the false discovery rate, at a level of significance of 0.05. Of note, recruitment will continue until 20 participants in each group, injured and uninjured are collected, as injury may be unknown at time of recruitment. Analysis will be exploratory and a number of anatomical measures will be compared between outcome groups. These measures include nostril size, and columella and septal width. We will also investigate a surface deviation analysis (voxel by voxel differences) between outcome groups by averaging 3D scans within groups. Demographics will be compared between using statistical hypothesis tests to ensure inter-group homogeneity. Anatomical measures of facial morphology will be compared between two outcome groups. Differences between groups will be analyzed using hypothesis testing (parametric on non-parametric tests selected based on the distribution of the recorded data). The null hypothesis is that facial features are not associated with facial injuries in preterm infants who receive CPAP treatment.
Query!
Recruitment
Recruitment status
Completed
Query!
Date of first participant enrolment
Anticipated
1/09/2022
Query!
Actual
6/12/2022
Query!
Date of last participant enrolment
Anticipated
28/02/2023
Query!
Actual
11/09/2023
Query!
Date of last data collection
Anticipated
24/03/2023
Query!
Actual
11/09/2023
Query!
Sample size
Target
40
Query!
Accrual to date
Query!
Final
41
Query!
Recruitment in Australia
Recruitment state(s)
QLD
Query!
Recruitment hospital [1]
21961
0
Royal Brisbane & Womens Hospital - Herston
Query!
Recruitment postcode(s) [1]
37055
0
4029 - Herston
Query!
Funding & Sponsors
Funding source category [1]
310995
0
Charities/Societies/Foundations
Query!
Name [1]
310995
0
RBWH Foundation
Query!
Address [1]
310995
0
Block 20, Central Drive,
Royal Brisbane & Women's Hospital
Butterfield St
Herston, Qld, 4006
Query!
Country [1]
310995
0
Australia
Query!
Primary sponsor type
Hospital
Query!
Name
Metro North Health
Query!
Address
Level 14, Block 7
Royal Brisbane & Women's Hospital
Herston, Qld, 4029
Query!
Country
Australia
Query!
Secondary sponsor category [1]
312309
0
None
Query!
Name [1]
312309
0
Query!
Address [1]
312309
0
Query!
Country [1]
312309
0
Query!
Other collaborator category [1]
282365
0
Other Collaborative groups
Query!
Name [1]
282365
0
Herston Biofabrication Institute
Query!
Address [1]
282365
0
Level 12, Block 7
Royal Brisbane & Women's Hospital
Herston Queensland 4029
Query!
Country [1]
282365
0
Australia
Query!
Other collaborator category [2]
282366
0
Other Collaborative groups
Query!
Name [2]
282366
0
Queensland Institute of Medical Research Berghofer
Query!
Address [2]
282366
0
300 Herston Rd,
Herston Qld 4029
Query!
Country [2]
282366
0
Australia
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
310548
0
RBWH HREC
Query!
Ethics committee address [1]
310548
0
Level 2, Building 34 Butterfield St Herston Qld 4029
Query!
Ethics committee country [1]
310548
0
Australia
Query!
Date submitted for ethics approval [1]
310548
0
16/02/2022
Query!
Approval date [1]
310548
0
26/04/2022
Query!
Ethics approval number [1]
310548
0
HREC/2021/QRBW/83811
Query!
Summary
Brief summary
Nasal continuous positive airway pressure (CPAP) is the most common method of respiratory support used in the care of preterm infants. Injury to the nose from nasal CPAP occurs frequently (25% of infants using CPAP), potentially causing permanent scarring and disfigurement. Infants most at risk, are those born < 30 weeks gestation and < 1250g. Current nasal interfaces for CPAP available in the Grantley Stable Neonatal Unit (GSNU), come in a limited number of sizes and do not fit all faces. 3D printed custom fitted CPAP masks hold promise for reducing the risk of nasal injury from CPAP in this vulnerable population. This study will gather preliminary data to determine the best 3D scanning technique, to identify facial features that predispose preterm infants to CPAP nasal injuries. This is the first step towards the development of custom fitted CPAP masks to be manufactured, in house, at Metro North’s Herston Biofabrication Institute (HBI).
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
118042
0
Dr Melissa Lai
Query!
Address
118042
0
Grantley Stable Neonatal Unit
Level 5, Ned Hanlon Building
Royal Brisbane & Women's Hospital
Butterfield St, Herston, Qld 4029
Query!
Country
118042
0
Australia
Query!
Phone
118042
0
+61 7 3646 8918
Query!
Fax
118042
0
+61 7 3646 5259
Query!
Email
118042
0
[email protected]
Query!
Contact person for public queries
Name
118043
0
Melissa Lai
Query!
Address
118043
0
Grantley Stable Neonatal Unit
Level 5, Ned Hanlon Building
Royal Brisbane & Women's Hospital
Butterfield St, Herston, Qld 4029
Query!
Country
118043
0
Australia
Query!
Phone
118043
0
+61 7 3646 8918
Query!
Fax
118043
0
+61 7 3646 5259
Query!
Email
118043
0
[email protected]
Query!
Contact person for scientific queries
Name
118044
0
Melissa Lai
Query!
Address
118044
0
Grantley Stable Neonatal Unit
Level 5, Ned Hanlon Building
Royal Brisbane & Women's Hospital
Butterfield St, Herston, Qld 4029
Query!
Country
118044
0
Australia
Query!
Phone
118044
0
+61 7 3646 8918
Query!
Fax
118044
0
+61 7 3646 5259
Query!
Email
118044
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
No
Query!
No/undecided IPD sharing reason/comment
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF