Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12621001264875
Ethics application status
Approved
Date submitted
2/08/2021
Date registered
17/09/2021
Date last updated
31/08/2023
Date data sharing statement initially provided
17/09/2021
Date results provided
31/08/2023
Type of registration
Prospectively registered
Titles & IDs
Public title
A trial to assess the visual performance of spectacle films in short-sighted young adults
Query!
Scientific title
Prospective, single-masked, randomised, bilateral wear, dispensing trial to assess the visual performance of spectacle films in myopic young adults
Query!
Secondary ID [1]
304451
0
None
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Myopia
322268
0
Query!
Condition category
Condition code
Eye
319951
319951
0
0
Query!
Diseases / disorders of the eye
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
This trial will be a prospective, bilateral, randomised, single-masked (participant), cross-over clinical trial. Participants will wear up to 11 different test spectacles with lens films (at optometrist’s discretion) and control spectacles. All the test films are configured with peripheral optical features to purposefully create peripheral retinal defocus, which has been shown to reduce the rate of myopia progression when applied to both spectacles and contact lenses. The location of the optical features within the films are configured differently between the 11 test designs, both in terms of the number of optical features contained in each film and in the orientation and placement of each optical feature. One example of the test design is D1O2, where D1 denotes the design number of the optical features and O2 denotes the orientation and placement of the optical features. The final pair of test films within the spectacles is then known as N1 through to N11. The lens films will be specifically designed for this trial by nthalmic. Lens films are made of polycarbonate material and are visually clear. All spectacles will be worn for up to 5 days for a minimum of 6 hours/day, there is no limit to the maximum hours spectacles are worn.
Participants will choose a frame design from a designated pool of standard test frames. Fittings will be confirmed by an optometrist. The distance power of the spectacle lenses will be power-matched to the participant's myopic refractive error. Participants will be dispensed new frames and lenses for each test, but each participant will use the same model and size frame with the same prescription for each lens film.
Each participant will attend for up to 5 visits, depending on the number of test spectacles with lens films that are worn. Assuming a participant wears 11 test spectacles with lens films, they will attend for 5 visits comprising visit 1 (baseline), visit 2 (1st set of spectacle lens dispensed), visit 3 (1st spectacle lens collection and 2nd set of spectacle lens dispensed), visit 4 (2nd spectacle lens collection and 3rd set of spectacle lens dispensed) and visit 5 (3rd spectacle lens collection). Up to four spectacles will be dispensed at visits 2, 3 and 4. There will be no spectacles given at baseline or visit 5 as this is the final spectacle collection visit.
Visit 1, 3 and 4 will be approximately 60min duration and visit 2 and visit 5 will be approximately 30min duration. The timing between visits will be approximately 2-3 weeks apart.
Visit 1 will comprise standard subjective refraction and measurement of visual acuity obtained with refraction. A standard logMAR visual acuity chart will be used. Spectacle lens dispense visits will include visual acuity measurements using standard logMAR visual acuity charts. Spectacle lenses will be dispensed. Spectacle collection visits will involve only the collection of used spectacles.
All assessments will be carried out by an optometrist.
Participants will be instructed to wear allocated spectacle lenses as per the schedule and return all spectacles.
There is no 'wash-out' period between treatments.
Compliance will be assessed by verbal questioning of participants.
Questionnaires will be administered to participants after each spectacle lens wear.
Query!
Intervention code [1]
320796
0
Treatment: Devices
Query!
Comparator / control treatment
There is one control in this trial: spectacle lenses with film with no optical features. This control spectacle film will be designed by nthalmic and is made of polycarbonate material. The film has no non-optical features..
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
327830
0
Subjective visual performance ratings between test and control spectacle films. Participants will be asked to rate their vision with each spectacle lenses on a non-validated 1-10 numeric rating scale
Query!
Assessment method [1]
327830
0
Query!
Timepoint [1]
327830
0
Following visit 2 (approximately 2 weeks post-enrolment): at 3 days, 8 days, 13 days and 18 days post visit 2 - primary timepoint
Following visit 3 (approximately 5 weeks post-enrolment): at 3 days, 8 days, 13 days and 18 days post visit 3 - primary timepoint
Following visit 4 (approximately 8 weeks post-enrolment): at 3 days, 8 days, 13 days and 18 days post visit 4 - primary timepoint
Query!
Secondary outcome [1]
396712
0
Visual acuity measures between test and control spectacle films. Visual acuity will be measured with standard logMAR chart at 6m
Query!
Assessment method [1]
396712
0
Query!
Timepoint [1]
396712
0
Visit 2: (approximately 2 weeks post-enrolment)
Visit 3: (approximately 5 weeks post-enrolment)
Visit 4: (approximately 8 weeks post-enrolment)
Query!
Secondary outcome [2]
398871
0
Binocular vision between test and control spectacle films.
Binocular vision assessments comprise the measurement of distance and near phoria and will be measured using the modified Thorington technique.
Query!
Assessment method [2]
398871
0
Query!
Timepoint [2]
398871
0
Visit 2: (approximately 2 weeks post-enrolment)
Visit 3: (approximately 5 weeks post-enrolment)
Visit 4: (approximately 8 weeks post-enrolment)
Query!
Secondary outcome [3]
399794
0
Contrast sensitivity measures between test and control spectacle films. Contrast sensitivity will be measured using a standard Pelli-Robson contrast sensitivity letter chart.
Query!
Assessment method [3]
399794
0
Query!
Timepoint [3]
399794
0
Visit 2: (approximately 2 weeks post-enrolment)
Visit 3: (approximately 5 weeks post-enrolment)
Visit 4: (approximately 8 weeks post-enrolment)
Query!
Eligibility
Key inclusion criteria
Able to read and comprehend English and give informed consent as demonstrated by signing a record of informed consent.
Be greater than or equal to 18 years old but less than or equal to 40 years old, male or female.
Willing to comply with the clinical trial as directed by the Investigator.
Have ocular health findings considered to be “normal” and which would not prevent the participant from wearing spectacle lenses.
Myopic spherical equivalent correction less than or equal to -0.75 D
A cylindrical correction greater than or equal to -2.00DC
Have best-corrected visual acuity at least 6/7.5.
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
40
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
Any pre-existing ocular irritation, injury, or condition (including infection or disease) of the cornea, conjunctiva or eyelids that would cause vision fluctuations.
Any systemic disease that adversely affects ocular health e.g. diabetes, Graves disease, and auto immune diseases such as ankylosing spondylitis, multiple sclerosis, Sjogrens syndrome, and systemic lupus erythematosus. Conditions such as systemic hypertension and arthritis do not automatically exclude prospective participants.
Eye surgery within 12 weeks immediately prior to enrolment for this trial.
Previous corneal refractive surgery .
Known allergy or intolerance to ingredients in spectacle frames .
Currently enrolled in another clinical trial.
Pregnancy at time of enrolment - verbal report sufficient
The Investigator may, at their discretion, exclude anyone who they believe may not be able to fulfil the clinical trial requirements or it is believed to be in the participant’s best interests.
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Allocation not concealed
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Simple randomisation using a randomisation table created by computer software
Query!
Masking / blinding
Blinded (masking used)
Query!
Who is / are masked / blinded?
The people receiving the treatment/s
Query!
Query!
Query!
Query!
Intervention assignment
Crossover
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Efficacy
Query!
Statistical methods / analysis
Each test spectacle lens film will be compared to one control. To demonstrate a statistically significant paired difference of 1.0 ± 1.5 units on a 1-10 numeric rating scale, and 5% significance, a sample of 39 participants will have > 80% power to allow comparisons between each test and the control spectacle film. The sample size is adjusted for a 10% drop-out.
Primary and secondary outcomes will be summarised as means ± standard deviation. Variable will be compared between the control and each test lens using parametric paired t-tests if the assumptions of data normality are not violated. Otherwise, Wilcoxon signed-rank test may be used. Multiple comparisons between all lens types will be assessed with descriptive statistics.
Query!
Recruitment
Recruitment status
Completed
Query!
Date of first participant enrolment
Anticipated
14/03/2022
Query!
Actual
23/03/2022
Query!
Date of last participant enrolment
Anticipated
Query!
Actual
4/08/2022
Query!
Date of last data collection
Anticipated
Query!
Actual
17/10/2022
Query!
Sample size
Target
39
Query!
Accrual to date
Query!
Final
44
Query!
Recruitment in Australia
Recruitment state(s)
NSW
Query!
Recruitment postcode(s) [1]
34337
0
2019 - Botany
Query!
Funding & Sponsors
Funding source category [1]
308811
0
Commercial sector/Industry
Query!
Name [1]
308811
0
nthalmic Pty Ltd
Query!
Address [1]
308811
0
Suite L2, Level 3, Lakes Business Park
2A Lord Street
Botany NSW 2019
Query!
Country [1]
308811
0
Australia
Query!
Primary sponsor type
Commercial sector/Industry
Query!
Name
nthalmic Pty Ltd
Query!
Address
Suite L2, Level 3, Lakes Business Park
2A Lord Street
Botany NSW 2019
Query!
Country
Australia
Query!
Secondary sponsor category [1]
309730
0
None
Query!
Name [1]
309730
0
Query!
Address [1]
309730
0
Query!
Country [1]
309730
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
308725
0
Bellberry Human Research Ethics Committee A
Query!
Ethics committee address [1]
308725
0
123 Glen Osmond Rd Eastwood South Australia 5063
Query!
Ethics committee country [1]
308725
0
Australia
Query!
Date submitted for ethics approval [1]
308725
0
04/08/2021
Query!
Approval date [1]
308725
0
28/09/2021
Query!
Ethics approval number [1]
308725
0
Query!
Summary
Brief summary
The purpose of this trial is to compare the visual performance of various spectacle films (test) against films without optical features (control). Visual performance will be assessed with vision testing and questionnaires completed by the participant. The films are made of polycarbonate material and have been designed to provide optical features for the use by people with short-sightedness. It is hypothesized the visual performance of test films will be no different to the control film.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
111674
0
Dr Daniel Tilia
Query!
Address
111674
0
nthalmic Pty Ltd
Suite L2, Level 3, Lakes Business Park
2A Lord Street
Botany NSW 2019
Query!
Country
111674
0
Australia
Query!
Phone
111674
0
+61 02 9037 7700
Query!
Fax
111674
0
Query!
Email
111674
0
[email protected]
Query!
Contact person for public queries
Name
111675
0
Kathleen Laarakkers
Query!
Address
111675
0
nthalmic Pty Ltd
Suite L2, Level 3, Lakes Business Park
2A Lord Street
Botany NSW 2019
Query!
Country
111675
0
Australia
Query!
Phone
111675
0
+61 02 9037 7700
Query!
Fax
111675
0
Query!
Email
111675
0
[email protected]
Query!
Contact person for scientific queries
Name
111676
0
Daniel Tilia
Query!
Address
111676
0
nthalmic Pty Ltd
Suite L2, Level 3, Lakes Business Park
2A Lord Street
Botany NSW 2019
Query!
Country
111676
0
Australia
Query!
Phone
111676
0
+61 02 9037 7700
Query!
Fax
111676
0
Query!
Email
111676
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
No
Query!
No/undecided IPD sharing reason/comment
Individual participant data will not be published. However trial results, recorded as group means plus / minus SD and their statistical analysis may be published in scientific journals
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF