Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12619000119190
Ethics application status
Approved
Date submitted
16/01/2019
Date registered
25/01/2019
Date last updated
25/01/2019
Date data sharing statement initially provided
25/01/2019
Type of registration
Prospectively registered
Titles & IDs
Public title
Immediate and short-term effect of magnetic tape on strength and mobility.
Query!
Scientific title
Immediate and short-term effect of magnetic tape on the strength of hip abduction and the joint degrees of hip rotations in adult healthy volunteers
Query!
Secondary ID [1]
297106
0
None
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Muscle dysfunction
311116
0
Query!
joint mobility limitation
311198
0
Query!
Condition category
Condition code
Musculoskeletal
309750
309750
0
0
Query!
Other muscular and skeletal disorders
Query!
Physical Medicine / Rehabilitation
309751
309751
0
0
Query!
Physiotherapy
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
The intervention is performed by a physiotherapist.
The people will be divided into two groups randomly. One experimental group and one control group.
Each test consists of recording the maximum strength of the hip abduction in the first isometry of one lower limb and after the other in the supine decubitus position. Subsequently, the patient is placed in a sitting position and performs an internal and external maximum rotation of each hip actively. The rotations are then evaluated passively. The tape is then placed without adhering it between the anterior superior iliac crests to immediately afterwards measure the maximum force and the joint range in rotation. After ten minutes the tape is removed from the body and the strength and joint range of the rotations are measured again.
Each subject of the both groups will be given 3 repetitions of each test and the average value will be obtained. The duration of each test will be 3 seconds.
The time used in each session to perform the tests is 30 minutes.
At 24 hours without the tape, the maximum force and the rotation of the hip will be tested again.
Force and joint tests are standardized by other publications.
The experimental group will be the application of magnetic fields less than 50 Hz for 10 minutes between the anterior superior iliac spines using a magnetic tape without adhering the tape as it is an adhesive tape but we want not to intervene the possible tension produced by the adhesion of the tape in the body.
The control group will be the one that apply a tape without magnetic properties. Both tapes are equal to sight and touch.
The tape remains in place as the force test is performed in supine so no need for restraint and to assess the hip rotation in sitting position is held with the waist of the pants.
With the application of low intensity magnetic fields we intend to normalize the electrical signal that reaches the pelvic musculature helping to normalize the tone of the periarticular muscles, equalizing the force produced by both limbs and equaling the degrees of rotation of both hips. force and joint tests are standardized by other publications.
The maximum force, time to perform the maximum force and average force produced when performing abduction of lower limbs using the Lafayette dynamometer and a goniometer to assess the degrees of mobility of the hip joint bilaterally will be assessed.
One of the tapes will be numbered with the number one and the other tape with the number two. The decision of which tape will take each number will be made at the moment of beginning the study using the same random program to group the subjects. Said information will only be known to the principal investigator and this will tell the physiotherapist what number of the tape to use in each subject as indicated by the random designation program.
The subject will not know what kind of tape is what they have.
Query!
Intervention code [1]
313373
0
Treatment: Devices
Query!
Comparator / control treatment
Each test consists of recording the maximum strength of the hip abduction in the first isometry of one lower limb and after the other in the supine decubitus position. Subsequently, the patient is placed in a sitting position and performs an internal and external maximum rotation of each hip actively. The rotations are then evaluated passively. The tape is then placed without adhering it between the anterior superior iliac crests to immediately afterwards measure the maximum force and the joint range in rotation. After ten minutes the tape is removed from the body and the strength and joint range of the rotations are measured again.
At 24 hours without the tape, the maximum force and the rotation of the hip will be tested again.
Each subject of the both groups will be given 3 repetitions of each test and the average value will be obtained. The duration of each test will be 3 seconds.
The time used in each session to perform the tests is 30 minutes.
The tape will be placed between the anterior superior iliac spines without adhering the tape as it is an adhesive tape but we want not to intervene the possible tension produced by the adhesion of the tape in the body. Both tapes are equal to sight and touch.
The tape remains in place as the force test is performed in supine so no need for restraint and to assess the hip rotation in sitting position is held with the waist of the pants.
Each subject of the control group will be given 3 repetitions of each test and the average value will be obtained. The duration of each test will be 3 seconds.
The control group will be the one applied to the tape without producing magnetic fields for 10 minutes between the anterior superior iliac spines.
Strength and joint tests standardized by other publications are used to measure strength by performing abduction of hip in supine decubitus and hip rotation in sitting.
The maximum force, time to perform the maximum force and average force produced when performing abduction of lower limbs using the Lafayette dynamometer and a goniometer to assess the degrees of mobility of the hip joint bilaterally will be assessed.
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
318710
0
Maximum force of hip abduction in supine decubitus using The Lafayette Manual Muscle Testing (MMT) System.
Query!
Assessment method [1]
318710
0
Query!
Timepoint [1]
318710
0
Force, 2 days
Query!
Primary outcome [2]
318711
0
Average force of hip abduction movement in supine decubitus using The Lafayette Manual Muscle Testing (MMT) System.
Query!
Assessment method [2]
318711
0
Query!
Timepoint [2]
318711
0
Average force, 2 days
Query!
Secondary outcome [1]
365784
0
The range of mobility in external rotation of the hip actively in sitting position using a standardized goniometer.
Query!
Assessment method [1]
365784
0
Query!
Timepoint [1]
365784
0
2 days
Query!
Secondary outcome [2]
366019
0
The range of mobility in internal rotation of the hip actively in sitting position using a standardized goniometer.
Query!
Assessment method [2]
366019
0
Query!
Timepoint [2]
366019
0
Internal rotation of the hip actively, two days
Query!
Secondary outcome [3]
366020
0
The range of mobility in external rotation of the hip passively in sitting position using a standardized goniometer.
Query!
Assessment method [3]
366020
0
Query!
Timepoint [3]
366020
0
external rotation of the hip passively, two days.
Query!
Secondary outcome [4]
366021
0
The range of mobility in internal rotation of the hip passively in sitting position using a standardized goniometer.
Query!
Assessment method [4]
366021
0
Query!
Timepoint [4]
366021
0
internal rotation of the hip passively, two days
Query!
Eligibility
Key inclusion criteria
No surgical interventions with prostheses in the lower limbs or rachis.
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
60
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
Yes
Query!
Key exclusion criteria
Have a pacemaker.
Be pregnant.
Any contraindication to the application of magnetic fields.
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Query!
Masking / blinding
Blinded (masking used)
Query!
Who is / are masked / blinded?
The people receiving the treatment/s
The people administering the treatment/s
The people assessing the outcomes
The people analysing the results/data
Query!
Query!
Query!
Query!
Intervention assignment
Parallel
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Efficacy
Query!
Statistical methods / analysis
The subjects of the study are people without specific pathology and also healthy recruited from the degree and postgraduate of the University of Valencia. It is intended to create two groups of at least 20 subjects each. A series of repeated-measures ANOVAs measures will be performed.
Query!
Recruitment
Recruitment status
Not yet recruiting
Query!
Date of first participant enrolment
Anticipated
18/02/2019
Query!
Actual
Query!
Date of last participant enrolment
Anticipated
15/03/2019
Query!
Actual
Query!
Date of last data collection
Anticipated
22/03/2019
Query!
Actual
Query!
Sample size
Target
40
Query!
Accrual to date
Query!
Final
Query!
Recruitment outside Australia
Country [1]
21207
0
Spain
Query!
State/province [1]
21207
0
Valencia
Query!
Funding & Sponsors
Funding source category [1]
301671
0
University
Query!
Name [1]
301671
0
University of Valencia, Spain
Query!
Address [1]
301671
0
Departament de Fisioteràpia
Facultat de Fisioteràpia
Universitat de València
C/ Gascó Oliag, 3
46010 Valencia
Query!
Country [1]
301671
0
Spain
Query!
Primary sponsor type
Individual
Query!
Name
Francisco Selva Sarzo
Query!
Address
Departament de Fisioteràpia
Facultat de Fisioteràpia
Universitat de València
C/ Gascó Oliag, 3
46010 Valencia
Query!
Country
Spain
Query!
Secondary sponsor category [1]
301388
0
None
Query!
Name [1]
301388
0
None
Query!
Address [1]
301388
0
None
Query!
Country [1]
301388
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
302390
0
Comité Ético de Investigación en Humanos de la Universidad de Valencia
Query!
Ethics committee address [1]
302390
0
Avenida Blasco Ibañez 13 46010 Valencia España
Query!
Ethics committee country [1]
302390
0
Spain
Query!
Date submitted for ethics approval [1]
302390
0
07/01/2019
Query!
Approval date [1]
302390
0
10/01/2019
Query!
Ethics approval number [1]
302390
0
H1547569414958
Query!
Summary
Brief summary
The purpose of this study is to increase the maximum and average strength of the hip abduction in supine decubitus and the improvement of joint movement (ROM) of hip rotation in sitting. The hypotheses of the study are: - When a low intensity magnetic field is applied between the anterior superior iliac spines, an increase in force is produced when hip abduction is performed and an increase in ROM of hip rotation is produced. - Immediately after the application of the magnetic field there is a significant increase in the average force performed during the 3-second test when hip abduction is performed and the range of motion of the hip rotations is improved. - After 10 minutes of application, the significant increase in the average force during the 3-second test is maintained when performing the hip abduction and the range of movement of the hip rotations. - After 24 hours from the treatment of magnetic fields for 10 minutes, the significant increase in force and range of motion of the hip rotations is maintained.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
90070
0
Dr Francisco Selva Sarzo
Query!
Address
90070
0
Departament de Fisioteràpia
Facultat de Fisioteràpia
Universitat de València
C/ Gascó Oliag, 3
46010 Valencia
Query!
Country
90070
0
Spain
Query!
Phone
90070
0
+34 96 386 43 95
Query!
Fax
90070
0
Query!
Email
90070
0
[email protected]
Query!
Contact person for public queries
Name
90071
0
Francisco Selva Sarzo
Query!
Address
90071
0
Departament de Fisioteràpia
Facultat de Fisioteràpia
Universitat de València
C/ Gascó Oliag, 3
46010 Valencia
Query!
Country
90071
0
Spain
Query!
Phone
90071
0
+34 96 386 43 95
Query!
Fax
90071
0
Query!
Email
90071
0
[email protected]
Query!
Contact person for scientific queries
Name
90072
0
Francisco Selva Sarzo
Query!
Address
90072
0
Departament de Fisioteràpia
Facultat de Fisioteràpia
Universitat de València
C/ Gascó Oliag, 3
46010 Valencia
Query!
Country
90072
0
Spain
Query!
Phone
90072
0
+34 96 386 43 95
Query!
Fax
90072
0
Query!
Email
90072
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
Yes
Query!
What data in particular will be shared?
All individual participant data relating to force and range of motion outcomes will be shared.
Query!
When will data be available (start and end dates)?
Beginning 3 months and ending 5 years following main results publication
Query!
Available to whom?
for everyone
Query!
Available for what types of analyses?
for all
Query!
How or where can data be obtained?
link
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF