Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12610000204044
Ethics application status
Approved
Date submitted
23/02/2010
Date registered
10/03/2010
Date last updated
12/11/2013
Type of registration
Prospectively registered
Titles & IDs
Public title
Lid Wiper Epitheliopathy: Exploring the links with osmolality and ocular comfort during contact lens wear
Query!
Scientific title
A prospective, randomised, double-masked, controlled, cross-over study of the effects of wearing lotrafilcon A versus comfilcom A silicone hydrogel lenses for up to 10 days on lid wiper epitheliopathy in healthy lens wearing participants.
Query!
Secondary ID [1]
1477
0
None
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
lid wiper epitheliopathy
256872
0
Query!
Condition category
Condition code
Eye
257023
257023
0
0
Query!
Diseases / disorders of the eye
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
Participants will be randomised to wear either lotrafilcon A silicone hydrogel contact lenses on a daily wear basis for up to 10 days OR comfilcon A silicone hydrogel contact lenses on a daily wear basis flor up to 10 days and then, following a washout period of 7 days where no lenses are worn, crossed over to the other lens group.
Hydrogen peroxide disinfection system (AOSept or Omnicare) will be used for disinfection after each day of wear.
Query!
Intervention code [1]
256066
0
Diagnosis / Prognosis
Query!
Intervention code [2]
256125
0
Other interventions
Query!
Comparator / control treatment
No lens wear during wash out periods of 7 days duration before interventions. The effect of the two interventions will be compared to each other and to the no lens wear condition following the 1 week washout period.
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
257915
0
Lid wiper epitheliopathy grade (o to 3)
Query!
Assessment method [1]
257915
0
Query!
Timepoint [1]
257915
0
baseline and after up to 10 days after intervention commencement
Query!
Secondary outcome [1]
263397
0
contact lens osmolality (mmol/kg) measured using a vapour pressure osmometer
Query!
Assessment method [1]
263397
0
Query!
Timepoint [1]
263397
0
after up to 10 days after intervention commencement
Query!
Secondary outcome [2]
263398
0
Ocular comfort rating (1 to 100 scale)
Query!
Assessment method [2]
263398
0
Query!
Timepoint [2]
263398
0
baseline and after up to 10 days after intervention commencement
Query!
Eligibility
Key inclusion criteria
Ability to wear contact lenses, no contraindications to lens wear, no lens wear in the past 7 days
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
No limit
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
Yes
Query!
Key exclusion criteria
Required use of any ocular eye drops other than unit dose saline rewetting drops during the study period
Query!
Study design
Purpose of the study
Diagnosis
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Query!
Masking / blinding
Blinded (masking used)
Query!
Who is / are masked / blinded?
The people receiving the treatment/s
The people assessing the outcomes
Query!
Query!
Query!
Query!
Intervention assignment
Query!
Other design features
Query!
Phase
Query!
Type of endpoint/s
Query!
Statistical methods / analysis
Query!
Recruitment
Recruitment status
Completed
Query!
Date of first participant enrolment
Anticipated
1/05/2010
Query!
Actual
23/09/2010
Query!
Date of last participant enrolment
Anticipated
Query!
Actual
30/11/2010
Query!
Date of last data collection
Anticipated
Query!
Actual
Query!
Sample size
Target
20
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
Query!
Funding & Sponsors
Funding source category [1]
256570
0
Self funded/Unfunded
Query!
Name [1]
256570
0
Query!
Address [1]
256570
0
Query!
Country [1]
256570
0
Query!
Funding source category [2]
288254
0
Charities/Societies/Foundations
Query!
Name [2]
288254
0
British Contact Lens Association
Query!
Address [2]
288254
0
7/8 Market Place, London W1W 8AG
Query!
Country [2]
288254
0
United Kingdom
Query!
Primary sponsor type
University
Query!
Name
School of Optometry and Vision Science
Query!
Address
c/o Dr Isabelle Jalbert
School of Optometry and Vision Science
The University of New South Wales
Entry via Gate 14, Barker Street
Rupert Myers Building (North Wing)
Kensington NSW 2033
Query!
Country
Australia
Query!
Secondary sponsor category [1]
255865
0
None
Query!
Name [1]
255865
0
Query!
Address [1]
255865
0
Query!
Country [1]
255865
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Summary
Brief summary
This project aims to deepen our understanding of the causes of discomfort during contact lens wear. Participants will wear two types of contact lenses (lotrafilcon and comfilcon) for up to 10 days at a time.The project hypothesises that there is a link between the saltiness of peoples' tears, of their contact lenses and the presence of superficial damage to the portion of the upper eyelid that wipes over the contact lens and the sensation of discomfort during lens wear.
Query!
Trial website
Query!
Trial related presentations / publications
1. Stahl U, Delaveris A, Madigan M, Jalbert I. Lid wiper epitheliopathy: exploring the links to comfort and osmolality in contact lens wear. British Contact Lens Association Annual Clinical Conference (BCLA) 2011, Manchester, UK, 2011. 2. Delaveris N, Stahl UG, Madigan M, Jalbert I. Do lissamine green strips from various manufacturers perform equally? Clin Exp Optom 2011;94: 613-614.
Query!
Public notes
Query!
Contacts
Principal investigator
Name
30875
0
Dr Isabelle Jalbert
Query!
Address
30875
0
School of Optometry and Vision Science
The University of New South Wales
Sydney, NSW 2052, Australia
Query!
Country
30875
0
Australia
Query!
Phone
30875
0
+61-2-9385-9816
Query!
Fax
30875
0
Query!
Email
30875
0
[email protected]
Query!
Contact person for public queries
Name
14122
0
Dr Isabelle Jalbert
Query!
Address
14122
0
School of Optometry and Vision Science
The University of New South Wales
Sydney, NSW 2052
Query!
Country
14122
0
Australia
Query!
Phone
14122
0
+61-2-9385-9816
Query!
Fax
14122
0
Query!
Email
14122
0
[email protected]
Query!
Contact person for scientific queries
Name
5050
0
Dr Isabelle Jalbert
Query!
Address
5050
0
School of Optometry and Vision Science
The University of New South Wales
Sydney, NSW 2052
Query!
Country
5050
0
Australia
Query!
Phone
5050
0
+61-2-9385-9816
Query!
Fax
5050
0
Query!
Email
5050
0
[email protected]
Query!
No information has been provided regarding IPD availability
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF